Controlled Bonding Trial Matrix | Tengyang
Tengyang controlled-trial tool

Controlled Bonding Trial Matrix

Build a seven-condition, one-factor-at-a-time sequence around one baseline. The matrix helps identify which control direction changes the result; it does not establish a universal production setting.

Define the baseline and step size

Hold material lot, substrate preparation, construction, cooling and verification method constant.

Seven-condition comparison

7 conditions21 specimens
ConditionHeat (°C)Dwell (s)Pressure (MPa)RepeatObservation

Use the matrix as a diagnostic sequence

Do not change adhesive grade, surface preparation or cooling method inside this sequence. If the safe equipment or material range cannot accommodate a step, reduce it before running specimens and record that decision.