Get in touch with Tengyang Company
Bond Exposure Comparison
Compare an initial joint result with its result after the exposure you specified. Use the same measurement unit and a comparable test setup for both values.
Enter your trial values, then calculate.
Calculation and interpretation
Retained result (%) = exposed result ÷ initial result × 100. Change = exposed result − initial result.
A value above 100% is possible; report it without calling it a pass. This tool does not predict service life or supply an acceptance limit. Record exposure time, environment, specimen identity and failure location separately. Values must be 0–1,000,000,000; the initial result must be at least 0.000001 to keep the ratio within the supported numeric range.
Discuss Your Lamination Trial